Quality & Certifications

Simplicity and reliability are key. That’s why we have a no-compromise approach to quality for every product. For you, this means products you can rely on for better success rates that are safe for the patient.

Quality & Certifications 1
Quality & Certifications 3

Quality is our cornerstone

Our products undergo thorough quality testing before being released, to ensure consistent quality for your piece of mind. Our focus on quality at every level of our operations is audited and confirmed by our notified bodies, that delivers quality certificates. Feedback from customers is crucial. We welcome your thoughts and suggestions as you are the source of inspiration for improvements to our products.

EC, ISO Certifications and Licenses

CooperGenomics

Based on location, CooperGenomics laboratories hold various global licenses, certifications, and accreditations, serving as a safe and reliable laboratory partner. We are proud to be certified, licensed, and/or accredited by the following:

Quality Testing Across Our Brands

Ultra Clean Manufacturing

All manufacturing and packaging is carried out in a state-of-the-art cleanroom which is certified to ISO 14644 class 7. Special filters remove particles, bacteria, VOCs, and other airborne and volatile contaminants. The cleanroom is maintained spotlessly clean and undergoes regular microbiological screening. To minimize contamination, personnel wear a full set of cleanroom garments – coverall, hood, overshoes, gloves, and mask. Gloves are rinsed and decontaminated regularly during use and undergo regular microbiological screening. Only ultrapure water is used: > 18.2 MΩ per cm, TOC < 10 ppb, bacteria < 1 CFU per 500 ml, endotoxins < 0.03 EU per ml. These measures maintain an ultraclean manufacturing environment which ensures ultraclean, sterile pipettes.

Quality Assurance

We aim to provide the highest quality pipettes and microtools through rigorous quality control and quality assurance with certification to ISO 13485, excellent customer service, and technical support.

Manufacturing Quality Control

Every pipette is checked and measured repeatedly during manufacture and inspected by an experienced technician before packaging to ensure that they are intact, clean, and comply with specifications. Strict rejection criteria are used during all stages of manufacturing. Pipettes which do not strictly conform to specifications and standards of cleanliness are rejected without compromise. We discard what other manufacturers sometimes package and sell.

Batch Quality Assurance

Every batch is tested by an independent laboratory using a validated mouse embryo assay (MEA). To maximize sensitivity: (i) one-cell zygotes are cultured to fully expanded blastocysts (FEB); (ii) a simple culture medium is used to slightly ‘stress’ the embryos; (iii) protein-free culture medium is used so that toxicity is not masked by protein; (iv) embryos are directly exposed to pipette tips for the entire 96 hour culture period. Every batch is also tested by an experienced embryologist using a micromanipulator set up to ensure that pipettes are ultraclean, non-sticky, and function smoothly and efficiently under routine micromanipulation conditions.

Other Quality Assurance Procedures

The cleanroom is maintained spotlessly clean, undergoes regular microbiological screening, and is certified to ISO 14644 class 7. Water systems are rigorously maintained, tested regularly for bacteria and endotoxins, and certified annually by the manufacturer. Packaging materials are thoroughly inspected and tested to ensure cleanliness and sterility. Packaging and sterilization processes are fully validated to a Sterilization Assurance Level (SAL) of 10.

Guarantee of Quality

If any of our pipettes have manufacturing defects, we will gladly replace them free of charge.

Sterility and Biocompatibility Testing

RI’s range of consumables must pass stringent testing and inspection criteria to ensure that you receive the most consistent and high quality product.

Mouse Embryo Assay (MEA) for embryo toxicity

Each sterility batch of finished product is tested by an independent laboratory using a 1-cell stage mouse embryo toxicity test. Embryos are also assessed at critical development points during the MEA to ensure maximum test sensitivity. Non-embryotoxic proven by Mouse Embryo Assay (MEA), Pass Level: Day 2 ≥80% 2-cells, Day 6 ≥80% blastocysts.

Limulus Amoebocyte Lysate (LAL) for endotoxins

Each sterility batch of finished product is tested for bacterial endotoxins. Our pass criteria is < 20Eu per device.

Human Sperm Survival Assay (HSSA)

Each sterilization batch of finished injection pipettes within the RI Pipette range undergoes a sperm motility bioassay. To pass the HSSA test, the motility of sperm should be ≥ 70% after 24 hours of sample preparation.

Sterilization

Where applicable, products are sterilized by an approved gamma irradiation facility meeting ISO 11137 standards to a sterility assurance level (SAL) of 10-6. The shelf life of our pouch packed products is 3 years and for our blister packed products, 5 years.

Device Approval

All RI medical devices carry the CE mark. The CE mark shows that RI’s products comply with the Essential Safety Requirements of the European Medical Device Directive (93/42/EEC) as amended. Many of our medical devices also have USA FDA market clearance, Health Canada medical device licenses, and certification in Taiwan and China. We are continuously working to expand our registration with the relevant medical device authorities across the world.

ART Media

Monitoring and quality control testing cover all processes from the receipt of raw materials to the final product, including product development.

The final products are tested with a combination of the following QC tests according to our specifications:

  • pH test: Ph. Eur., USP current edition
  • Osmolality test: Ph. Eur., USP current edition
  • Mouse Embryo Assay (MEA): Embryos are cultured in test medium and control medium for 72 hours (for 2-cell) or 96 hours (for 1-cell) respectively. ORIGIO requires a minimum of 80% formation rate to expanded blastocysts. All relevant final products are tested by a MEA test.
  • Endotoxin LAL test: Ph.Eur., USP current edition
  • Sterility test: Ph.Eur., USP current edition. All products are sterile filtered and each batch is tested for sterility.
  • Sperm Survival Test: This test is intended to demonstrate the absence of substances that will reduce the viability of spermatozoa. The Sperm Survival Test is based on CASA (Computer Assisted Semen Analysis). Determination of VAP (average path velocity), VSL (straight-line velocity) and VCL (curvilinear velocity) is used to calculate the concentration of motile spermatozoa. After incubation in media the survival rate must be ≥ 80%.
  • Sperm Immobilization Test: Sperm with normal motility characteristics are mixed with the media. To pass the test, VSL of the sperm suspended in the media must be reduced by more than 70%.

Note: The results from each batch are stated on a certificate of Analysis, which is available here.

Humagen Pipets

Mouse Embryo Assay (MEA): Each master lot of micropipet glass and Pasteur pipets are tested for toxicity in a one-cell mouse embryo assay (MEA). The percentage of embryos exposed to the micropipets or Pasteur pipets that develop to the blastocyst stage are compared to control embryos. The embryos are assessed at 96 hours of culture. The product and control is assessed and the product will be considered non-toxic if the percentage of blastocysts exposed to the product is greater than or within 10% of the control percentage. Seventy percent or more of the control embryos must reach the blastocyst stage for the test to be considered valid.

Endotoxin LAL test: Each master lot of micropipet glass and Pasteur pipets is endotoxin tested using the Limulus Amebocyte Lysate (LAL) assay. Each lot must be less than 20 endotoxin units per device to pass. Specific testing information and results can be found on the Certificate of Analysis provided with each lot of micropipets and Pasteur Pipets. In addition, independent laboratory tests of packaging, sterilization and expiration date validation are conducted on all products during design and upon changes to materials or production.

Note: The results from each batch are stated on a certificate of Analysis, which is available here.

Needles and Catheters
  • Mouse Embryo Assay (MEA)
  • Endotoxin LAL test

Note: The results from each batch are stated on a certificate of Analysis, which is available here.

Cryopette®, Stripper® tips
  • Mouse Embryo Assay (MEA)
  • Sterility test
  • Endotoxin LAL test

Note: The results from each batch are stated on a certificate of Analysis, which is available here.

Quality documents

ORIGIO has obtained CE markings for a range of its products. The CE mark covers most of our ORIGIO products including among others: media, pipets, the Stripper® and Cryopette®.

The CE mark ensures that the products comply with the relevant European health and safety legislation. IVF products are covered by the Medical Device legislation and therefore ORIGIO’s products do comply with the Essential Safety Requirements in the European Medical Device Directive (93/42/EEC).

Our Global Laboratory and Production Facilities

Quality & Certifications 5

Alajuela, Costa Rica

Our production facility for media, needles and catheters as well as pipettes.

Quality & Certifications 7

Falmouth, United Kingdom

Hardware and consumables from Research Instruments (RI) are manufactured and packaged at this site. It holds certification to EN ISO 13485:2012 (including CMDCAS) and Medical Device Directive
93/42/EEC as amended

Quality & Certifications 9

CooperGenomics, North America

Laboratory locations in North America
Houston, TX
Livingston, NJ
Los Angeles, CA
Toronto, ON

Quality & Certifications 11

CooperGenomics, United Kingdom

Laboratory locations in the United Kingdom London, England

Quality & Certifications 13

Get In Touch With Us

We’d love to hear from you. How can we help?